Phased-Array-Geräte

OmniScan M für das Prüfen von Hand

OmniScan

Watch the 15 min OmniScan M Presentation Video >>

Phased Array Solutions for the Price of Conventional UT

The new model in the OmniScan® product line provides the advantage of phased array imaging for manual testing, while keeping all the benefits of a proven product.

Choosing OmniScan MX as your entry point into phased array technology allows you to keep all your options open for the future. The OmniScan MX is fully upgradable to any other model of the OmniScan series, allowing you to migrate to encoded inspection, data archiving, and automated UT inspection as your needs grow.

OmniScan

Features

Ease of Use

  • Live switch between conventional UT and phased array
  • Intuitive data interpretation
  • Software control of beam angle, focal distance, and spot size
  • Multiple-angle inspection with a single, small, electronically controlled multielement probe
  • Step-by-step calibration wizard eases the entry of every parameter, avoiding mistakes
  • Focal law calculator wizard
  • Automatic probe recognition
  • Minimum training required

Imaging

  • Support for up to 64-element probes
  • Beam forming using 16 elements
  • Real-time volume-corrected representation of S-scans at 40 Hz with selectable A-scans
  • Vertically projected A-scan is displayed alongside the S-scan
  • "Most relevant A-scan" tracking mode
  • Large 8.4 in. color display

Setup and Report

  • Exportable setup parameters
  • Thorough report setup including readings, images, and parameters
  • On-screen interactive HTML help
  • Predefined setups with preview

Detection and Sizing

  • Increased probability of detection and better defect sizing
  • Code compliance, in both PA and UT
  • Defect sizing tools
  • S-scan and image recording

Field Proven

  • Rugged PA connector with automatic probe recognition
  • Affordable
  • Portable, reliable, and durable
  • Battery-powered (up to 8 hours)
  • Upgradable
  • Modular and multitechnology

Module Specifications

General
Overall dimensions 244 mm x 182 mm x 57 mm
(9.6 in. x 7.1 in. x 2.1 in.)
Weight 1.2 kg (2.6 lb)
Connectors 1 OmniScan connector for phased array probes
2 BNC connectors (1 pulser/receiver,
1 receiver for conventional UT)
Number of focal laws 256
Probe recognition Automatic probe recognition and setup
Pulser/Receiver
Aperture (active elements) Up to 16 elements
Number of elements 16 or 64 elements
Pulser
Voltage 80 V per element
Pulse width Adjustable from 30 ns to 500 ns, resolution of 2.5 ns
Fall time Less than 10 ns
Pulse shape Negative square wave
Output impedance Less than 25 Ω
Receiver
Gain 0-74 dB maximum input signal 1.32 V p-p
Input impedance 75 Ω
System bandwidth 0.75 MHz to 18 MHz (-3 dB)
Beam forming
Scan type Azimuthal and linear
Delay range transmission 0-10 µs in 2.5-ns increments
Data processing
Rectifier RF, full wave, halfwave +, halfwave -
Filtering Low-pass (adjusted to probe frequency), digital filtering (bandwidth, frequency range)
Data visualization
A-scan refresh rate Real-time: 60 Hz
Volume-corrected S-scan Up to 40 Hz
Data synchronization
PRF 1 Hz to 10 kHz
Programmable time-corrected gain (TCG)
Number of points 16 (1 TCG curve per channel for focal laws)