Industrial Testing Instruments

OmniScan MX UT

Ultrahang

Ultrasound Inspection

Time-of-Flight Diffraction Testing

Time-of-flight diffraction (TOFD) is a technique that uses two probes in pitch-catch mode. TOFD detects and records signals diffracted from defect tips allowing both detection and sizing. The TOFD data is displayed in a grayscale B-scan view. TOFD offers wide coverage and amplitude-independent sizing complying with the ASME‑2235 code.

  • One-line scan for full-volume inspection
  • Setup independent of weld configuration
  • Very sensitive to all kinds of defects and unaffected by defect orientation
TOFD and Pulse-Echo Testing


While TOFD is a very powerful and efficient technique, its coverage is limited as a result of two inspection dead zones: one dead zone is near the surface, the other is at the backwall.

The OmniScan® UT allows inspections that simultaneously combine TOFD with conventional pulse echo. Pulse echo complements TOFD, covering the dead zones.

  • TOFD inspection
  • 45º pulse echo for weld cap inspection on either side of the weld
  • 60º pulse echo for weld root inspection on either side of the weld
0‑Degree Testing (Corrosion and Composite)

0-degree testing measures the time-of-flight and amplitude of ultrasonic echoes reflecting from the part into gates in order to detect and measure defects.
  • C‑scan imaging
  • Full A‑scan recording with C‑scan postprocessing

Ultrasound Software

Full-Featured C‑Scan

  • Monitors amplitude, peak position, crossing level position, and thickness on each gate.
  • Automatic gate synchronizes from previous gate for higher dynamic range of thickness.
  • A‑scan data storage and C‑scan postprocessing capabilities
  • Optional IF gate for surface-following synchronization or measurement gate, or TCG/DAC curves
  • Positive or negative gate on RF signal (independent for each gate)
  • Eight completely configurable alarms on single-gate events or multiple-gate events, filter for n occurrences from one or multiple channels
  • Customizable color palette for amplitude and thickness C‑scans
  • Adjustable 256-level color palette
  • 2‑axis mechanical encoding with data-acquisition synchronization on mechanical movement
  • Optional data library to access A‑scans and/or C‑scans on PCs for custom processing
Full-Featured B‑Scan
  • Easy-to-interpret cross-sectional view of inspected part
  • Excellent display of corrosion mapping for boilers, pipes, and storage tanks
  • Visual identification of acquired thickness values
  • Encoded TOFD capability for amplitude-independant defect sizing
Full-Featured A‑Scan

  • Color‑selectable A‑scan display
  • Reject mode
  • Hollow mode
  • Peak-hold mode (always keeps the signal that shows the maximum amplitude in gate A)
  • Gate threshold-level crossing (changes the color of the curve that is over the gate level)
  • 60-Hz A‑scan refresh rate with overlays of envelope and peak inside the gate
Step-by-Step Calibration Wizards

All calibration procedures are guided using step-by-step wizards.

  • Sound velocity calibration
  • Wedge delay calibration
  • TOFD calibration
  • TCG calibration
  • Encoder calibration
TOFD Option

  • B-scan encoded data imaging and storage
  • Grayscale color palette, adjustable for brightness and contrast
  • 100-MHz A‑scan digitizing
  • TOFD calibration wizard, online and offline
  • Hyperbolic cursor and reading for TOFD sizing
  • Lateral wave resynchronization

Ultrasound Module Specifications

Overall dimensions
(W x H x D)
244 mm x 182 mm x 57 mm
(9.6 in. x 7.1 in. x 2.1 in.)
Weight1 kg (2.2 lb)
ConnectorsLEMO® 00 (2, 4, or 8)
Pulser
Number of pulsers2, 4, or 8
Pulse output50 V, 100 V, 200 V, 300 V ±10 %
(variable pulse width)
Pulse widthAdjustable from 30 ns to 1000 ns ±10 %, resolution of 2.5 ns
Fall timeLess than 7 ns
Pulse shapeNegative square wave
Output impedanceLess than 7 Ω
Receiver
Number of receivers2, 4, or 8
Receiver gain range0 dB to 100 dB, by steps of 0.1 dB
Maximum input signal20 Vp-p (screen at 128 %)
Minimum sensitivity200 µVp-p (screen at 128 %)
Noise referred to input160 µVp-p (26 µV RMS) (128 %)
Input impedance50 Ω
Input filter
(100 % bandwidth)
Centered at 1 MHz (1.5 MHz),
centered at 2 MHz (2.25 MHz),
centered at 5 MHz (4 MHz),
centered at 10 MHz (12 MHz),
centered at 15 MHz,
centered at 20 MHz;
0.25 MHz to 2.5 MHz, 2 MHz to 25 MHz BB
System bandwidth0.25 MHz to 32 MHz (-3 dB)
RectifierBoth, positive, negative
ModePE (pulse-echo), PC (pitch-catch), TT (through-transmission). In PC mode the maximum number of pulsers equals the number of channels divided by 2.
SmoothingDigital
DAC
Number of points16
DAC rangeUp to 40 dB
Maximum gain slope20 dB/µs
Data acquisition
A-scan acquisition rate6000 A-scans/s (512-point A-scan)
Maximum pulsing rate1 channel at 12 kHz (C-scan)
Data processing
Real-time averaging2, 4, 8, 16
Gates
Quantity3: I (synchro), A and B (measure)
SynchronizationI, A, B referenced on main bang; A and B referenced on gate I (post-synchronization)
Data storage
A-scan recording (TOFD)6000 A-scans/s (512-point A-scan)
(3 MB/s transfer rate)
C-scan type data recording12 000 (A1, A2, A3, T1, T2, T3) (3 gates)
12 kHz
(lower frequency for corrosion mapping)
Data visualization
Refresh rate60 Hz
Data synchronization
On time1 Hz to 12 kHz
On encoderOn 1 or 2 axes divided into 1 to 65 536 steps
Alarms
Number3
ConditionsAny logical combination of gates
SignalAmplitude or TOF of gate A or B

Single-Axis Encoded B-Scan Inspection

Introducing the OmniScan 2-channel UT B-Scan Corrosion Mapping Kit.

This kit includes the OmniScan MX UT, the manual Remote Scan B-scan position encoder, TomoView Lite software, and a dual-UT probe. This kit addresses your B-scan inspection needs-for spot checks and one-line scans on ferrous steel structures, plates, pipes, and more.

Remote Scan, B-scan position encoder OmniScan MX UT (2 channels) TomoView Lite for postprocessing
English | 日本語 | français | 中文 | Deutsch | italiano | čeština | magyar Español | Tiểng Việt |