| Type of material | Carbon steel, bearing steel, spring steel, nikel-based steel | | Line speed | 1 m/s | | Diameter range | 15 mm to 75 mm (0.55 in. to 3 in.) | | Code requirement | Application program interface (API) | | Bar length | 2 m to 10 m | | Straightness of bar | Up to 4 mm/m (pre-centering device to reject bent bars) | | Volume inspection | Longitudinal waves at 0° and angled | | Surface inspection | Shear waves at optimized angle to detect surface defects | | Distance between bars | 1.2 m to 1.5 m | | Length at ends not inspected | <50 mm |
Defects to Be Detected
| Calibration |
FBH 0.7 mm or equivalent SDH |
| Detection of calibration defect |
0.35 mm x 5 mm |
| Defect |
Volume defects caused by the manufacturing process |
Description of the Solution
Acoustic approach for the inspection of bars
• Four phased-array probes covering each 90 degrees
• High-accuracy centering during inspection
• Beam focus at different depth according to the diameter of the bar
• Electronic beam rotation for 360 degrees
• One set of four phased-array probes to cover a diameter variation of 25 mm Mechanical requirements
• Cover diameters ranging from 10 mm to 100 mm
• Water cell for local immersion
• Continuous inspection with minimum end of bar untested
• Four degrees of freedom to adapt to tube movement
• Water cell with unique auto centering capability
• Positioning table to adapt to all diameters
• Pinch roller and automation with PLC to close and open powerful roller

Electronic scanning with a virtual aperture
of 16 elements moving along the length of the probe. 
Curved phased-array probe covering 90 degrees of bar.

Electronic scanning with two angles for bar inspection: 0° LW and 40° SW. Electronic focusing at different
depths to accommodate different diameters.

Two motorized pinch rollers on each side Cassette with autocentering device of the immersion tank. The
immersion tank is equipped with two cassettes holding two phased-array probes each. The immersion tank includes a
water management system at both ends.
Software
• Dedicated software with bar wizard, and operator and supervisor levels
• Setup loading for complete system configuration
• Bar wizard for new bar diameter and wall thickness
• Electronic scanning function for sensitivity adjustment for each probe
• Automatic calibration sequence
• Data available on Microsoft® Access data table
• A-scan display and strip chart
Performance of the System
Defect detection
- Defect FBH 0.7 mm with SNR >15 dB
- Defect 0.35 mm x 5 mm with SNR >12 dB
- Inspection speed: 1.2 m/s
- End of bar not inspected: <10 mm
- Setup loading for each diameter
- Focusing at different depths according to the diameter of the bar to control
- Volume inspection with a focused ultrasound beam adapted to each diameter
- Inspection of surface defect using angle inspection; detection of surface defect 0.2 mm to 5 mm

Strip chart presentation of data from each probe.

Bar wizard to configure the setup for new bar diameter.
 |
| Strip chart showing FBH defect 0.35 mm. |
For the supervisor level, A-scan, C-scan, and strip chart display. FBH 0.7
mm at different depths 2 mm to 15.5 mm with SNR from 10 dB to 15 dB. |
System
• Cabinet
• 2 QuickScan PA 32:256
• PC and monitor
• Programmable logic controller (PLC)
|